“The tenascin-XB (TNXB) gene has antiadhesive effects, fun


“The tenascin-XB (TNXB) gene has antiadhesive effects, functions in matrix maturation in connective tissues, and localizes to the major histocompatibility complex class III region. We hypothesized that it may influence adaptive physiological response through an effect on blood vessel function. We identified a novel g.1324 A -> G polymorphism at a TaqI recognition site in a 454 bp fragment of ovine TNXB and genotyped

it in 150 Nigerian sheep using PCR-RFLP. The missense mutation changes glutamic acid (GAA) to glycine (GGA). Among SNP genotypes, significant differences (P < 0.05) were observed in body weight and fore cannon bone length. Interaction effects of breed, SNP genotype, and geographic location had a significant effect (P < 0.05) on chest girth. The SNP genotype was significantly (P < 0.05) associated BI 6727 cost with physiological traits of pulse rate and skin temperature. The observed effect of this novel polymorphism may be mediated through its role in connective tissue biology, requiring further association and functional studies.”
“Objective: We compared the performance of McMaster Premium LiteratUre Service (PLUS) CCI-779 and Clinical Queries (CQs) to that of the Cochrane Controlled Trials Register, MEDLINE, and EMBASE for locating studies added during an update of reviews.

Study Design and Setting: A sample of

new studies in updated Cochrane systematic reviews was used as a reference standard. Searches were performed for each study in each database. Where a new study was not indexed in PLUS, we examined the effect on the review of excluding the study.

Results: Ninety-eight updated Cochrane reviews were identified. For the 87 reviews with a usable meta-analysis, PLUS contained all new studies for 13 reviews. No statistically significant difference between PLUS and non-PLUS new studies was found when ratio of odds ratios (RORs) were pooled across 39 reviews (ROR(circle plus/circle dot): 0.99; 95% confidence

interval: 0.87-1.14). Thirty-five updated reviews had no new studies indexed in PLUS, but conclusions were seldom altered by addition of new Proteases inhibitor studies.

Conclusions: PLUS included less than a quarter of the new studies in Cochrane updates, but most reviews appeared unaffected by the omission of these studies. Reviewers should consider adopting PLUS and CQ filters to improve the efficiency of keeping their reviews up to date. (C) 2012 Elsevier Inc. All rights reserved.”
“The instrumentation of the osteoporotic spine may sometimes result in failure due to the loosening or pullout of the conventional pedicle screw. Moreover, augmentation of screws with polymethylmethacrylate (PMMA) has risks of complications. We developed a new and original pedicle nail system with PMMA for osteoporotic vertebral fractures. A clinical evaluation of this novel pedicle nail system utilized in patients with an osteoporotic vertebral collapse was performed to determine the effectiveness and safety of this technique.

Comments are closed.